| Pureshield™ |
| Natural Rubber Latex Examination Gloves, Non-Sterile |
| • PS1000 : Powdered |
| • PS2000 : PF Single Chlorinated |
| • PS3000 : PF Polymer Coated |
| • PS5500 : PF Double Chlorinated |
| • PS9000 : PF 13 Mil, Long Cuff |
| |
| Pureshield™ |
| Natural Rubber Latex Gloves (Industrial), Non-Sterile |
| • PS1001 : Powdered |
| • PS3001 : PF Polymer Coated |
 |
|
 |
| CHEMAX 7th Sense™ |
| Low Dermatitis Potential : Nitrile Examination Gloves, Non-Sterile |
| • CX7000 |
| • CX7500 |
 |
|
 |
| Nitrifil™ |
Nitrile Examination Gloves,
Non-Sterile |
| • NF9500 : PF, Long Cuff |
 |
|
 |
| INtouch™ |
| Natural Rubber Latex Surgical Gloves, Sterile |
| • INTOUCHW01S : Powdered |
| • INTOUCHW02S : Powdered, Non-Beaded |
| • INTOUCHW03S : PF Damp Donning |
| • INTOUCHW04S : PF Single Chlorinated |
| • INTOUCHW05S : PF Polymer Coated |
 |
| INtouch™ V natural |
| Natural Rubber Latex Examination Gloves, Sterile |
| • INTOUCHW01E : PF Polymer Coated |
 |
| INtouch™ V synthetic |
| Nitrile Examination Gloves, Sterile |
| • INTOUCHW02E : PF, Long Cuff |
 |
| INtouch™ PRO |
| Natural Rubber Latex Procedure Gloves, Non-Sterile, Hand Specific, Long Cuff |
| • INTOUCHW01P : Powdered |
| • INTOUCHW02P : PF Polymer Coated |
| |
|
| • Medical Examination • Sterile Procedure |
|
| |
|
| iNtouch™ V natural - INTOUCHW01E |
Powder Free Polymer Coated Latex
Examination Gloves, Sterile |
| |
|
 |
| Physical Dimension : |
Glove Size |
Glove Length (mm) |
Glove Width (mm) |
ASTM
D3578-05
Specification |
Our Typical
Product
Performance |
ASTM
D3578-05
Specification |
Our Typical
Product
Performance |
XS |
Min.220 |
242 - 245 |
70 ± 10 |
76 - 79 |
S |
Min.220 |
242 - 245 |
80 ± 10 |
83 - 85 |
M |
Min.230 |
242 - 245 |
95 ± 10 |
94 - 96 |
L |
Min.230 |
242 - 245 |
111 ± 10 |
104 - 106 |
XL |
Min.230 |
242 - 245 |
N/A |
115 - 117 |
|
| |
Glove Thickness – Single Wall (mm) |
Glove Length (mm) |
ASTM D3578-05
Specification |
Our Typical Product
Performance |
Cuff Thickness (25mm from bead) |
N/A |
0.10 - 0.11 |
Palm Thickness (centre of palm) |
Min. 0.08 |
0.14 - 0.15 |
Finger Thickness (13mm from tip) |
Min. 0.08 |
0.16 – 0.17 |
|
| |
| |
| Physical Properties : |
Parameter |
Unaged |
Aged |
ASTM
D3578-05
Specification |
Our Typical
Product
Performance |
ASTM
D3578-05
Specification |
Our Typical
Product
Performance |
Tensile Strength, MPa |
Min.18 |
21.0 - 23.0 |
Min. 14 |
19.0 - 22.0 |
Modulus @ 500%, MPa |
Max.5.5 |
3.0 - 4.0 |
N/A |
3.5 – 4.8 |
Ultimate Elongation, % |
Min.650% |
740 - 820 |
Min.500% |
690 - 800 |
Force at Break, N |
Min. 9 |
9.5 – 10.0 |
Min. 6 |
8.5 – 9.0 |
|
| |
| |
| Protein Content : |
Glove Protein Content |
ASTM D5712-05 Specification |
Our Typical Product Performance |
Max. 2mg/glove |
20 - 25 |
|
| |
| |
| Glove Powder Free Residue Content : |
Glove Powder Free Residue Content |
ASTM D6124-06 Specification |
Our Typical Product Performance |
Max. 2mg/glove |
0.10 – 0.15 |
|
| |
| |
| Pre-shipment Inspection Program |
Inspection Parameter |
Defect Description |
Inspection Plan :
Level / AQL |
Dimension |
• Glove Thickness (Cuff/Palm/Fingers)
• Glove Width
• Glove Length |
S – 2 / 4.0 |
Physical Properties
(Before and After Aging) |
• Tensile Strength
• Modulus
• Ultimate Elongation
• Force at Break (EN455 Only) |
S – 2 / 4.0 |
|
• Major Defects
• Minor Defects |
|
1000ml Water Tight Test |
• Holes / Leaks |
G – I / 1.5 |
Powder Free Residue |
• Powder Residue Content |
N = 5 |
Protein |
• Protein Content |
N = 3 |
|
| |
| |
| Other Product Information |
Packing Configuration |
100 pieces per dispenser, 10 dispensers per carton
= 1000 pieces per carton |
Lot Number Structure |
YYYY-XXX
(YYYY = year of manufacture, XXX= Julian Day) |
Recommended Shelf Life |
3 years upon manufactured date |
Sterilization Method |
Gamma Irradiation |
|
|